Cooling equipment tubes
Round copper tubes for manufacturing equipment cooling and air conditioning units
Medidas:
Exterior Ø 6.35 to 66.67 mm.
Data sheet
Select the different categories of information to generate a personalized PDF file.
At Bronmetal we supply high quality round, square, rectangular and oval copper tubes for cooling equipment.
Material Designation | Chemical Composition in % (m/m) |
Density2 g/cm3 approx.
|
|||
---|---|---|---|---|---|
Symbolic | Numerical | Element | Cu1 | P | |
Cu-DHP
|
CW024A
|
min. | 99,90 | 0,015 |
8,9
|
max. | – | 0,040 | |||
1 Including silver, up to a maximum of 0.015%.
|
|||||
2 Only for information.
|
Nominal exterior diameter d |
Nominal Wall Thickness e mm |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Metric Series | Imperial Series | |||||||||||||||
mm | mm | in | 0,28 | 0,30 | 0,35 | 0,40 | 0,45 | 0,50 | 0,63 | 0,70 | 0,80 | 1,00 | 1,25 | 1,50 | 1,65 | 2,00 |
6,35 | 1/4 | ● | ● | ● | ● | |||||||||||
7 | ● | ● | ● | ● | ||||||||||||
7,94 | 5/16 | ● | ● | ● | ● | |||||||||||
8 | ● | ● | ● | ■ ● | ||||||||||||
9,52 | 3/8 | ● | ● | ■ ● | ● | ● | ● | ■ | ||||||||
10 | ● | ● | ■ ● | ● | ■ ● | ● | ■ | |||||||||
12 | ● | ● | ● | ● | ■ | ● | ■ | |||||||||
12,70 | 1/2 | ● | ● | ■ ● | ■ ● | ■ ● | ● | ■ | ||||||||
14 | ■ | ■ | ||||||||||||||
15 | ● | ● | ● | ● | ||||||||||||
15,87 | 5/8 | ● | ● | ■ ● | ● | ● | ■ | ■ | ||||||||
16 | ● | ● | ■ ● | ■ | ● | ■ | ■ | |||||||||
18 | ■ | ■ | ||||||||||||||
19,06 | 3/4 | ■ | ■ | |||||||||||||
20 | ■ | ■ | ■ | |||||||||||||
22 | ■ | ■ | ■ | |||||||||||||
22,23 | 7/8 | ■ | ||||||||||||||
25,40 | 1 | ■ | ||||||||||||||
28 | ■ | |||||||||||||||
28,57 | 1 1/8 | ■ | ■ | |||||||||||||
34,92 | 1 3/8 | ■ | ||||||||||||||
35 | ■ | |||||||||||||||
41,27 | 1 5/8 | ■ | ||||||||||||||
42 | ■ | |||||||||||||||
53,97 | 2 1/8 | ■ | ■ | |||||||||||||
54 | ■ | |||||||||||||||
64 | ■ | |||||||||||||||
66,67 | 2 5/8 | ■ | ||||||||||||||
NOTE – This table is the first step towards a norm which only includes metric values. | ||||||||||||||||
■ Available in straight lengths. | ||||||||||||||||
● Available in rolls. |
SURFACE QUALITY
The interior and exterior surfaces of the piping must be clean and smooth.
Any residue left over after solvent has evaporated must not exceed 38 mg/m2 of the internal surface.
Treatment State | Yield Limit with 0.2% deformation | Tensile Strength | Elongation | Grain size | |||
---|---|---|---|---|---|---|---|
Rp0.2 | Rm | A | µm | ||||
Designation in line with Norm EN 1173 | Common Term | MPa | MPa | % | |||
min. | max | min. | min. | min. | max. | ||
Y080a | superficial hardening | 80 | 140 | 220 | 40 | 15 | 40 |
Y040 | light annealed | 40 | 90 | 220 | 40 | 15 | 40 |
Y035b | soft annealed | 35 | 80 | 210 | 40 | 30 | 60 |
NOTE – MPa equivalent to 1 N/mm2 | |||||||
a Only straight lengths. | |||||||
b Nominal wall thickness e > 0.6 mm. |
Nominal Exterior Diameter | Tolerances on nominal diameter | |||
---|---|---|---|---|
d | Applicable to mean diameter | Applicable to any diametera | ||
greater than | less than or equal to | All Treatment States | State R290 (hard) | State R250 (semi-hard) |
3 | 18 | ± 0,04 | ± 0,04 | ± 0,09 |
18 | 28 | ± 0,05 | ± 0,06 | ± 0,10 |
28 | 54 | ± 0,06 | ± 0,07 | ± 0,11 |
54 | 76,1 | ± 0,07 | ± 0,10 | ± 0,15 |
76,1 | 88,9 | ± 0,07 | ± 0,15 | ± 0,20 |
88,9 | 108 | ± 0,07 | ± 0,20 | ± 0,30 |
a Including ovalization. |
Nominal Exterior Diameter | Tolerances for wall thickness ea | |
---|---|---|
d | e < 1 mm | e ≥ 1 mm |
mm | % | % |
< 18 | ± 10 | ± 13 |
≥ 18 | ± 10 | ± 15 |
a Including excentricity. |
Select one of the previous options before downloading the personalized file
Value Copper
10/10/2022
Previous value
07/10/2022
0,00 €/Ton